AI ready data centers

An AI data center is a facility purpose-built to handle the intensive compute, power, and cooling demands of artificial intelligence workloads. Unlike traditional data centers designed for general-purpose computing, these facilities feature high-density power delivery, specialized cooling systems, and low-latency networking that allow GPUs to operate at full capacity without bottlenecks or thermal throttling.

As organizations move from AI experimentation to production-scale deployment, the gap between what standard data centers can deliver and what AI workloads actually require has become impossible to ignore. Training a large language model or running real-time inference at scale puts extraordinary stress on infrastructure, and facilities that were built for conventional enterprise applications simply cannot keep up.

What does AI-ready mean for your data center?

Being AI-ready means a data center can support the unique demands of GPU-intensive workloads without compromise. This requires a fundamentally different approach to three core infrastructure elements: power delivery, thermal management, and network architecture.

Traditional enterprise servers might draw 5 to 10 kilowatts per rack. AI infrastructure operates in a different category entirely. A single NVIDIA DGX H100 system consumes over 10 kilowatts on its own. According to industry analysis, high-density AI training clusters typically require 40 to 60 kilowatts per rack, while large language model workloads demand at least 70 kilowatts. Supercomputing applications can draw 100 kilowatts or more. The newest GPU architectures push these numbers even higher, with rack densities reaching 120 to 150 kilowatts for certain configurations.

This shift has significant implications for how AI data center facilities must be designed, built, and operated.

Power requirements for AI workloads

AI data center infrastructure requires power density that would have seemed extreme just a few years ago. The latest NVIDIA GB200 systems can require rack densities of up to 132 kilowatts at peak load, and future generations are expected to push well beyond these figures.

Supporting this kind of power draw requires more than simply upgrading electrical panels. Facilities need scalable, redundant power delivery systems that can handle concentrated loads without creating single points of failure. This includes higher-capacity uninterruptible power supplies, upgraded switchgear, and distribution architectures designed specifically for high-density deployments.

Electrical infrastructure must also be flexible enough to accommodate growth. AI projects tend to scale quickly once they prove their value, and organizations need the ability to add capacity without major facility overhauls.

Cooling strategies for high-density clusters

When racks consume 40 to 150 kilowatts of power, virtually all of that energy converts to heat—traditional air cooling struggles to remove enough thermal energy from these dense configurations. Air-based systems can use up to 40% of a facility's total electricity consumption, and they hit practical limits somewhere around 30 to 40 kilowatts per rack.

This is why high-density data center deployments increasingly rely on liquid cooling solutions. Direct-to-chip cooling circulates liquid coolant through cold plates attached directly to processors, removing heat far more efficiently than air alone. This approach can support rack densities of 50 to 100 kilowatts while reducing cooling energy consumption by as much as 90% compared to traditional methods.

For the highest-density configurations, immersion cooling offers another option. This technique submerges entire servers in dielectric fluid, which absorbs heat directly from all components simultaneously. Immersion systems can handle rack densities exceeding 150 kilowatts in some implementations.

Most AI facilities today use hybrid approaches. A typical configuration might rely on liquid cooling for 70 to 80% of thermal management, with air cooling handling the remainder. This combination allows facilities to address different cooling requirements across various components within the same infrastructure.

Networking for AI performance

AI workloads, particularly distributed training jobs, require GPUs to communicate constantly with one another. The network fabric connecting these processors directly affects how quickly models can be trained and how efficiently inference can be delivered.

Low-latency, high-bandwidth networking is essential for GPU-to-GPU communication. When thousands of processors need to synchronize gradients during training, even minor delays compound into significant performance penalties. Network bottlenecks can leave expensive GPU clusters sitting idle while they wait for data.

This means AI-ready facilities need network architectures designed for the specific traffic patterns of machine learning infrastructure. High-speed interconnects, optimized switching topologies, and careful attention to cable run lengths all contribute to the kind of performance that makes distributed AI workloads practical.

Why AI readiness matters for modern workflows

The infrastructure requirements described above are not just theoretical concerns. They translate directly into business outcomes: how quickly you can train models, how reliably you can serve predictions, and how cost-effectively you can scale as demand grows.

Organizations running AI workloads on inadequate infrastructure face predictable problems: training jobs take longer than they should, inference latency makes real-time applications impractical, and thermal throttling reduces GPU performance below rated specifications. These issues cost money in wasted compute time, delayed projects, and missed opportunities.

The impact of AI on data centers extends beyond individual workloads to reshape how organizations think about their entire infrastructure strategy.

Supporting training vs. inference

Training and inference place different demands on infrastructure, and understanding these differences matters for capacity planning.

Training large models requires massive, concentrated compute resources. Organizations typically centralize training workloads in facilities that can support the highest power densities and provide the fastest GPU interconnects. Training jobs may run for days or weeks, consuming substantial resources throughout.

Inference, by contrast, is often distributed across multiple locations to reduce latency for end users. Inference workloads may have lower per-rack power requirements than training, but they demand high availability and consistent performance. Many organizations find they need AI-ready capacity in multiple geographic regions to serve inference workloads effectively.

Understanding how your workload mix will evolve helps inform infrastructure decisions. Most organizations start with training requirements and then face growing inference demands as their models move into production.

Enabling scalability and sustainability

AI infrastructure needs to scale, and it needs to do so without creating unsustainable energy consumption.

The future of AI infrastructure depends on the industry's ability to meet growing compute demands while managing environmental impact. Facilities designed with efficiency in mind from the start can accommodate growth more responsibly than those retrofitted after the fact.

Liquid cooling contributes to sustainability by reducing the energy required for thermal management. Efficient power distribution minimizes losses between the utility connection and the servers. Smart facility management ensures that capacity is used effectively rather than wasted.

Organizations evaluating energy-efficient data centers should consider how well potential partners can support AI workloads while maintaining strong efficiency metrics. The two goals are not mutually exclusive, but achieving both requires intentional design.

How to know if your data center is AI-ready

When you're looking for infrastructure to support AI workloads, you need to know what separates facilities that can actually deliver from those that will hold you back. Many data centers that serve traditional enterprise applications well will struggle with AI deployments.

The checklist below can help you evaluate potential colocation partners and determine whether their facilities can meet your requirements.

AI-ready data center checklist

When evaluating a data center provider for AI workloads, ask about these key capabilities:

Power density: Can the facility deliver 40 kilowatts or more per rack? For large-scale training deployments, can it support 100 kilowatts or higher? Is there redundancy built into power delivery systems?

Cooling capacity: Does the facility offer liquid cooling options such as direct-to-chip or rear-door heat exchangers? Can cooling systems handle the thermal load of high-density GPU clusters without creating hot spots?

Network fabric: Is the network architecture designed for the traffic patterns of distributed AI workloads? Can it provide the low latency required for efficient GPU-to-GPU communication?

Monitoring and management: Does the facility provide visibility into power consumption, thermal conditions, and performance metrics at the rack level? Can you track efficiency and identify potential issues before they affect workloads?

Compliance and security: Does the facility meet the compliance standards relevant to your industry? Are physical and logical security controls adequate for the data involved in your AI projects?

Scalability: Can you add capacity as your AI workloads grow? Is there a clear path from initial deployment to larger-scale production?

Providers that can answer yes to these questions are positioned to support your AI deployments. Those who cannot may leave you constrained as your workloads grow.

Next steps to prepare for AI

Moving from AI experimentation to production requires infrastructure that can keep pace with your ambitions. The decisions you make now about where to deploy will shape what you can accomplish over the coming years.

Start by understanding your actual requirements. What models do you plan to train, and what inference workloads do you need to serve? How will those needs evolve as your AI initiatives mature?

Then evaluate potential partners against those requirements. Does the provider offer purpose-built machine learning infrastructure? Can they support your growth as workloads scale?

Building an effective AI strategy means aligning your infrastructure decisions with your business goals. The right partner makes everything that follows easier.

Request an AI strategy assessment

If your organization is preparing to deploy AI workloads and needs infrastructure that can support high-density power, advanced cooling, and low-latency networking, Flexential can help. Our AI-ready data centers are built to handle the demands of GPU-intensive training and inference at scale.

Talk to an expert about your AI infrastructure needs


FAQ

What does it mean for a data center to be AI-ready?

An AI-ready data center is designed to support the specific demands of artificial intelligence workloads, including high-density power delivery (typically 40 kilowatts per rack and above), advanced cooling systems capable of managing concentrated thermal loads, and low-latency networking optimized for GPU-to-GPU communication. These facilities can support both AI model training and inference at production scale.

Why do AI workloads require specialized power, cooling, and networking?

AI workloads rely on GPUs that consume far more power and generate far more heat than traditional servers. A single high-end AI server can draw over 10 kilowatts, and racks filled with these systems require power densities that standard facilities were never designed to handle. The heat produced requires cooling beyond what air-based systems can provide. And because AI training involves constant communication between processors, network performance directly affects how efficiently compute resources are used.

How much power density is needed to support AI infrastructure?

Requirements vary by workload. High-density AI training clusters typically need 40 to 60 kilowatts per rack. Large language model workloads often require 70 kilowatts or more. The newest GPU systems can push rack densities to 120 to 150 kilowatts, with future architectures expected to go even higher.

What cooling solutions are best for high-density AI clusters?

Liquid cooling has become the standard for high-density AI deployments. Direct-to-chip cooling, which circulates liquid through cold plates attached to processors, can support rack densities of 50 to 100 kilowatts. Immersion cooling, which submerges servers in dielectric fluid, can handle even higher densities. Most facilities use hybrid approaches that combine liquid and air cooling to address different requirements within the same infrastructure.

How does networking impact AI performance and scalability?

Network architecture significantly affects how quickly distributed training jobs complete and how efficiently inference workloads can be served. GPUs involved in training must constantly exchange data, and any network latency or bandwidth constraints reduce utilization of expensive compute resources. Facilities designed for AI provide high-bandwidth, low-latency connectivity optimized for the traffic patterns of machine learning workloads.

How can I determine if a data center provider can support my AI workloads?

Evaluate providers against the core requirements: power density capability (at least 40 kilowatts per rack for most AI workloads), cooling capacity (liquid cooling options for high-density deployments), network architecture optimized for GPU-to-GPU communication, monitoring tools, compliance posture, and room to scale. Many organizations find that working with colocation partners who have purpose-built AI infrastructure delivers better results than trying to retrofit existing facilities or build their own.

Accelerate your hybrid IT journey, reduce spend, and gain a trusted partner

Reach out with a question, business challenge, or infrastructure goal. We’ll provide a customized FlexAnywhere® solution blueprint.